diagsetburnin

Initializes the blade for a burn-in run.
Synopsis
diagsetburnin [--slot slotnumber][script | -current]
Availability
Admin
Release
V4.1.x
Description
This sets up the blade burnin parameters for the registered burnin script. The name
of burnin script can be set with burninname command alternatively. The
burnin will start at the next run of POST on the designated blades.
The errors and activity logs are stored in non-volatile memory. The activity log of
the script is saved in /var/log/scriptname.slot.log. The errors
produced are available from burninerrshow command on a per blade basis.
When power cycles occur, the burnin activity is restarted at the test that was
interrupted at the time of the power cycle. This command does not require a
reboot to take effect.
Operands
This command has the following operands:
--slot slotnumber
script
-current
Fabric OS Version 3.1.x/4.1.x Reference Guide
Specify which slot number to to update. If this option is
not specified at all, then all slots on the switch are setup
for burnin.
Specify the name of the burnin script to run.
Set the name of burnin script to current burnin script.