Fabric OS Commands

setgbicmode

Enable or disable GBIC mode.
Synopsis: V3.1.x
setgbicmode [mode]
Synopsis: V4.1.x
setgbicmode [mode | -show]
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to enable or disable the GBIC mode. If the mode operand is 1,
GBIC mode is enabled; if the mode operand is 0, GBIC mode is disabled. The
mode is saved in non-volatile memory and the GBIC remains in that mode until
the next execution of setgbicmode.
The mode becomes active as soon as this command is executed. It does not require
a reboot to take effect.
The GBIC mode, when enabled, forces crossPortTest and spinSilk to
limit testing to ports with GBICs present. Consequently, testing is limited to those
ports with a suspected problem.
Note:
Gb SAN switch use SFPs instead of GBICs. This command is now replaced by the
setsfpmode command. The command is included in the current Fabric OS for
backward compatibility of scripts used by some customers.