Fabric OS Commands
Example
To display the basic set of statistics for blade 2 port 3:
switch:admin> portstatsshow 2/5
stat_wtx
stat_wrx
stat_ftx
stat_frx
stat_c2_frx
stat_c3_frx
stat_lc_rx
stat_mc_rx
stat_mc_to
stat_mc_tx
tim_rdy_pri
tim_txcrd_z
er_enc_in
er_crc
er_trunc
er_toolong
er_bad_eof
er_enc_out
er_disc_c3
open
transfer
opened
starve_stop
fl_tenancy
nl_tenancy
frame_nozone
switch:admin>
See Also
portErrShow
portShow
612
24081
4-byte words transmitted
24081
4-byte words received
141
Frames transmitted
141
Frames received
0
Class 2 frames received
117
Class 3 frames received
12
Link control frames received
0
Multicast frames received
0
Multicast timeouts
0
Multicast frames transmitted
0
Time R_RDY high priority
0
Time BB_credit zero
0
Encoding errors inside of frames
0
Frames with CRC errors
0
Frames shorter than minimum
0
Frames longer than maximum
0
Frames with bad end-of-frame
612
Encoding error outside of frames
0
Class 3 frames discarded
0
loop_open
0
loop_transfer
0
FL_Port opened
0
tenancies stopped due to starvation
0
number of times FL has the tenancy
0
number of times NL has the tenancy
0
frames rejected due to zone protection
Fabric OS Version 3.1.x/4.1.x Reference Guide