Table 15: PortShow Display Fields (Continued)
Parity_err
2ndary_parity_err
CMI_bus_err
The second column shows Link Error Status Block counters.
The third column shows the number of F_RJTs and F_BSYs generated. For
L_Ports, the third column also shows the number of LIPs received, number of
LIPs transmitted, and the last LIP received.
Operands
This command has the following operands:
slotnumber
(V4.1.x only)
portnumber
Fabric OS Version 3.1.x/4.1.x Reference Guide
Field
Real Tx data parity error.
Secondary Tx data parity error. These are not real Tx
data parity errors but rather forced by the ASIC due to
certain central memory errors so that the transmitter will
abort the frame. This field will only be displayed when
there are errors.
Control message interface errors.
Specify the slot number for a StorageWorks Core switch.
For all other switches this operand is not required. The slot
number must be followed by a slash ( / ) and the port
number, so that each port is represented by both slot
number (1 through 4, or 7 through 10), and port number
(0 through 15).
The StorageWorks Core switch has a total of 1–10 slots.
Slot number 5 and 6 are control processor cards, and slot
1 through 4, and 7 through 10, are port cards. On each
port card, there are 16 ports counted from the bottom, 0 to
15.
Specify a port number. Valid values for port number vary
depending on the switch type. This operand is required.
Description