Modem Configuration and Profile
Command
Type
Set
Read
Test
The following table shows the +CMEE parameters.
<Parameter>
<n>
3-290
Syntax
Response/Action
AT+CMEE=[<n>]
OK
or:
+CME ERROR: <err>
AT+CMEE?
+CMEE: <n>
OK
AT+CMEE=?
+CMEE: (list of
supported <n>s)
OK
Table 3-193: +CMEE Parameters
0
Disable the +CME ERROR: <err> result code and use ERROR.
1
Enable the +CME ERROR: <err> or +CMS ERROR: <err> result codes and
use numeric <err> values or +STK ERROR: <err> result codes and use numeric <err>
values.
2
Enable the +CME ERROR: <err> or +CMS ERROR: <err> result codes and
use verbose <err> values or +STK ERROR: <err> result codes and use numeric <err>
values.
The default value is 0.
AT Commands Reference Manual
Remarks
The Set command enables or disables the
use of result code +CME ERROR: <err> as
an indication of an error relating to the
functionality of the G24.
The Read command returns the current
setting format of the result code.
The Test command returns values
supported by the terminal as a compound
value.