Motorola G24 Guide Developer's Manual page 280

At commands
Hide thumbs Also See for G24 Guide:
Table of Contents

Advertisement

Hardware Information
Using AT+IPR=<rate> with a <rate> value other than 9 and 0 disables the auto baud rate
detection feature. The entered baud rate is stored in the G24 and is restored after power up. The
G24 supports up to 57600 auto baud.
Notes:
Set
Read
Test
The following table shows the +IPR parameters.
Example
AT+IPR=6
OK
AT+IPR?
+IPR: 19200
OK
AT+IPR=?
+IPR: (0-13,300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800)
OK
3-196
+IPR is similar to +CBAUD, but with the ability to save.
ATZ command sets the G24 to default baud rate - Auto baud rate, and the saved baud rate
is restored only after power-up.
Command Type
Table 3-126: +IPR Parameters
<Parameter>
<n> <rate>
0
1
2
3
4
5
6
7
8
9
10
11
12
13
AT Commands Reference Manual
Syntax
AT+IPR=<n>
AT+IPR=<rate>
AT+IPR?
AT+IPR=?
Description
Auto baud rate
600
1200
2400
4800
9600
19200
38400
57600
Auto baud rate
115200
300
230400
460800
Response/Action
OK
or:
ERROR
+IPR: <rate>
+IPR: (list of supported <rate>s)
December 31, 2007

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents