Lucent Technologies MERLIN LEGEND Release 6.1 Feature Reference page 925

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Feature Reference 555-661-110
I
Applications
Integrated Solution III
You cannot install Automated Attendant as a standalone application but
only in conjunction with AUDIX Voice Power.
When an AUDIX Voice Power subscriber receives a voice mail message,
the Message LED on the telephone lights. To properly update Message
LEDs on system extensions, link each AVP mailbox with telephones
connected to the control unit.
If an AUDIX Voice Power mailbox is needed for a person with no
telephone, you must assign a phantom extension to the control unit.
You should synchronize AUDIX Voice Power time with system time.
For Integrated Administration, the MAP/5 provides a separate backup and
restore capability that saves the directory information on the hard disk. This
is available through the Backup and Restore menu options under
Maintenance.
The subscriber must have
Administration Extension Directory in order to be added to or deleted from
AUDIX Voice Power.
All extensions and lines that you program through Integrated
Administration must be idle.
Feature Interactions
Account Code Entry
Coverage
Group Calling
Labeling
IS CAS uses the account codes people enter before or during calls to
associate calls with accounts and individuals; these codes appear on IS
CAS reports.
An inside call on a VMI port that transfers to an inside extension does not
go to coverage, but continues to ring at the inside extension.
If a sender programs the telephone so that only outside calls are sent to
coverage, calls received on ICOM or SA buttons are not sent to voice
mail.
In Release 2.0 and later, outside calls that would normally proceed to
AUDIX Voice Power as coverage do not do so if the telephone that sends
the call to group coverage has activated Coverage VMS Off. No special
action is needed in AUDIX Voice Power programming to activate this
feature.
With integrated VMI ports, mode codes identify coverage calls that
overflow from one calling group to another calling group. As a result, the
overflow calling group's number appears in the Called Party field of the
mode code.
Names entered through the Integrated Administration Extension Directory
are sent to the control unit and are available through Switch Labeling
screens.
in the Applications field of the Integrated
6 5
Issue 1
August 1998
Page I-52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend

Table of Contents