Ipv6 Pim-Ssm Configuration Example - 3Com S7906E Configuration Manual

S7900e family release 6600 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

(*, FF0E::100)
RP: 1003::2 (local)
Protocol: pim-sm, Flag: WC
UpTime: 00:16:56
Upstream interface: Register
Upstream neighbor: 4002::1
RPF prime neighbor: 4002::1
Downstream interface(s) information:
Total number of downstreams: 1
1: Vlan-interface102
Protocol: pim-sm, UpTime: 00:16:56, Expires: 00:02:34

IPv6 PIM-SSM Configuration Example

Network requirements
Receivers receive VOD information through multicast. The receiver groups of different
organizations form stub networks, and one or more receiver hosts exist in each stub network. The
entire PIM domain operates in the SSM mode.
Host A and Host C are IPv6 multicast receivers in two stub networks N1 and N2.
Switch D connects to the network that comprises the IPv6 multicast source (Source) through
VLAN-interface 300.
Switch A connects to N1 through VLAN-interface 100, and to Switch D and Switch E through
VLAN-interface 101 and VLAN-interface 102 respectively.
Switch B and Switch C connect to N2 through their respective VLAN-interface 200, and to Switch E
through VLAN-interface 103 and VLAN-interface 104 respectively.
Switch E connects to Switch A, Switch B, Switch C and Switch D.
The SSM group range is FF3E::/64.
MLDv2 is to run between Switch A and N1, and between Switch B/Switch C and N2.
1-43