Setting The Interval Of Performing Statistics On Ports - 3Com 8807 Configuration Manual

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

92
C
13: E
HAPTER
THERNET
Setting the Interval of
Performing Statistics
on Ports
Enabling/Disabling
Jumbo Frames' Passing a
Card
P
C
ORT
ONFIGURATION
Perform the following configuration in Ethernet port view.
Table 73 Enabling/disabling flow control for the Ethernet port
Operation
Enable Ethernet port flow control
Disable Ethernet port flow control
By default, Ethernet port flow control is disabled.
Use the following configuration tasks to set the interval of performing statistics on
ports. The switch performs the statistics about the average speed during the
interval.
Perform the following configuration in Ethernet port view to set the interval of
performing statistics on ports.
Table 74
Set the interval of performing statistics on ports
Operation
Enter system view
Enter Ethernet port view
Enter PoS port view
Set the interval of performing
statistics on ports
During large throughput data switching, like file transmission, a card may
encounter jumbo frames larger than the standard Ethernet frame length. The
following command can be used to enable jumbo frames to pass a card or disable
them from passing a card.
Perform the following configuration in system view.
Table 75 Enabling/disabling jumbo frames' passing a card
Operation
Enable Jumbo frames to pass the card on a
specified slot, and set the maximum length of
Jumbo frames allowed to pass the card
Disable Jumbo frames from passing the card
on a specified slot
By default, jumbo frames are allowed to pass cards.
n
The system supports discrete values of Jumbo frame lengths ranging from 1536 to
10240. However, effective Jumbo frame values fall into several sections: the
Command
flow-control
undo flow-control
Command
system-view
Interface interface-type
interface-number
Interface interface-type
interface-number
flow-interval interval
Command
jumboframe enable [ jumboframe-value ]
slot slot-num
jumboframe disable slot slot-num
Description
-
Optional;
The interface-type argument
is the Ethernet port type
Optional;
The interface-type argument
is the PoS port type
Required;
The interval of performing
statistics on ports is 300
seconds by default

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

88108814

Table of Contents