3Com 8807 Configuration Manual page 832

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

832
C
71: I
HAPTER
NFORMATION
n
Configuration examples
of sending log to Linux
loghost
C
ENTER
information center loghost a.b.c.d facility configured on the switch. Otherwise,
the log information probably cannot be output to the loghost correctly.
Step 3: After the establishment of information (log file) and the revision of
/etc/syslog.conf, you should send a HUP signal to syslogd (system daemon),
through the following command, to make syslogd reread its configuration file
/etc/syslog.conf.
# ps -ae | grep syslogd
147
# kill -HUP 147
After the above operation, the switch system can record information in related log
files.
To configure facility, severity, filter and the file syslog.conf synthetically, you can
get classification in great detail and filter the information.
Network requirements
The Network requirements are as follows:
Sending the log information of the switch to LINUX loghost
The IP address of the loghost is 202.38.1.10
The information with the severity level above informational will be sent to the
loghost
The output language is English
All modules are allowed to output information
Network diagram
Figure 193 Network diagram
Switch
Switch
Switch
Configuration procedure
1 Configuration on the switch
# Enable information center
[SW8800] info-center enable
# Set the host with the IP address of 202.38.1.10 as the loghost; set the severity
level threshold value as informational, set the output language to English; set all
the modules are allowed output information.