3Com 8807 Configuration Manual page 752

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

752
C
65: RMON C
HAPTER
n
ONFIGURATION
64
: 0
256-511: 0
# Configure an event before configuring alarm and prialarm.
[SW8800]rmon event 1 log
[SW8800]display rmon event 1
Event table 1 owned by 3Com-rmon is VALID.
Description: null.
Will cause log when triggered, last triggered at 1days 01h:42m:09s.
#Configure an alarm group.
[SW8800]rmon alarm 1 1.3.6.1.2.1.16.1.1.1.4.1 10 delta rising_threshold 1000
1 falling_threshold 100 1 owner 3Com-rmon
[SW8800]dis rmon alarm 1
Alarm table 1 owned by 3Com-rmon is VALID.
Samples type
Variable formula
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
Latest value
# Configure an extended alarm group.
[SW8800]rmon prialarm 1 ((.1.3.6.1.4.1.2011.6.1.2.1.1.2.0-.1.3.6.1.4.1.2011.
6.1.2.1.1.3.0)*100/.1.3.6.1.4.1.2011.6.1.2.1.1.2.0) prialarm1 10 delta risi
ng_threshold 70 1 falling_threshold 50 1 entrytype forever
[SW8800]display rmon prialarm 1
Prialarm table 1 owned by null is VALID.
Samples type
Variable formula
2011.6.1.2.1.1.
3.0)*100/.1.3.6.1.4.1.2011.6.1.2.1.1.2.0)
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
The "0" in black means the memory of slot 0 is queried.
,
65-127
: 0
,
512-1023: 0
owner 3Com-rmon
: delta
: 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
: Ethernet2/1/1
: 10(sec)
: 1000(linked with event 1)
: 100(linked with event 1)
: risingOrFallingAlarm
: 0
: delta
: ((.1.3.6.1.4.1.2011.6.1.2.1.1.2.0-.1.3.6.1.4.1.
: prialarm1
: 10(sec)
: 70(linked with event 1)
: 50(linked with event 1)
: risingOrFallingAlarm
: 0
,
128-255
: 0
,
1024-max : 0

Hide quick links: