3Com 8807 Configuration Manual page 862

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

862
C
77: NQA C
HAPTER
Introduction to NQA
Configuration Tasks
ONFIGURATION
Table 818 Introduction to the configuration tasks of the ICMP test in NQA
Operation
Enter system view
Enable the client function of
the NQA
Configure the maximum
number of the test tasks
performed simultaneously
Set the NQA test group, enter
NQA test group view
Set the test type
Set the destination address to
be tested
Set the description
information of the test group
Set the timeout time for the
test operation
Set the number of probe
packets to be sent
Set the life time for NQA
ICMP test packet, that is, the
maximum number of hops
that a test packet can pass in
the network
Set the TOS value in the NQA
test packet header
Set the filler data size of the
test packet
Set the filler data of the test
packet
Command
system-view
nqa-agent enable
nqa-agent max-requests
max-number
nqa administrator-name
test-tag
test-type type
destination-ip ip-address
description text
timeout time
count times
ttl number
tos value
datasize size
datafill text
Remarks
-
Required;
By default, NQA client is
disabled.
Optional;
The default maximum number
of the test tasks performed
simultaneously is 5.
Required;
By default, the system creates
no test group.When a test
group is set, the system
automatically enter the NQA
test group view.
At present, ICMP type is the
only choice
By default, the test type is
ICMP type.
Required;
By default, no destination
address is set.
Optional;
By default, there is no
description information of the
test group.
Optional;
By default, the timeout time
for the test operaton is 3
seconds
Optional;
By default, one probe packet
is sent.
Optional;
By default, the maximum
number of hops that a test
packet can pass is 20
Optional;
By default, the TOS value in
the NQA test packet header is
0, that is , no special service is
specified
Optional;
By default, the filler data size
of the test packet is 56 bytes
(including no protocol header)
Optional;
By default, no filler data in the
test packet is empty.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

88108814

Table of Contents