Download Print this page

HMS Networks Anybus CompactCom 40 Network Manual page 92

Profinet irt transparent ethernet
Hide thumbs Also See for Anybus CompactCom 40:

Advertisement

®
Anybus
CompactCom
40 - PROFINET IRT Transparent
Ethernet
11.2. Energy Measurement Object (E4h)
11.2.1. Category
Extended
11.2.2. Object Description
This object defines a standardized way of reporting different types of measurement values (current, voltage,
power, energy etc.) from a measuring device.
Each instance, logical device, represents a group of measurement values for one separate measurement device.
Physically, measuring devices might be connected to a higher level network directly, or indirectly via a coupling
device. To enable host applications to implement either a direct or an indirect measuring device, the Anybus
CompactCom object model implies a 1:1 relationship between measuring device (a.k.a. logical device) and
instance number, where each instance attribute represent a group of measurement values (see list of instance
attributes below). The host application does not have to support all instance attributes listed.The command
Get_Attribute_Measurement_List is used towards the host application, to read out which measurement values
are supported by a device.
The table below shows an example of how the instances of the Anybus CompactCom object model maps to
PROFIenergy. PROFIenergy uses the Object number to address a logical device, while the Measurement ID refers
to the actual measurement value.
Instance number
Attribute number
(logical device)
(measurement value)
1
1
4
10
2
1
4
10
3
13
16
19
See also...
PROFIenergy Profile (page 25)
11.2.3. Supported Commands
Object:
Get_Attribute
Instance:
Get_Attribute
Get_Attribute_Measurement_List
Page 84 of 177
PROFINET
Obj nr
Measurement ID
0
1,2,3,31
4,5,6,32
7,8,9,33
1
1,2,3,31
4,5,6,32
7,8,9,33
2
10,11,12,36
13,14,15,34
16,17,18,35
Energy Measurement Object (E4h)
Description
Logical device #1
#1-Voltage PH-N
#4-Voltage PH-PH
#10-Current
Logical device #2
#1-Voltage PH-N
#4-Voltage PH-PH
#10-Current
Logical device #3
#13-Apparent Power
#16-Active Power
#19-Reactive Power
SCM-1202-021 Version 2.6

Advertisement

loading
Need help?

Need help?

Do you have a question about the Anybus CompactCom 40 and is the answer not in the manual?

Questions and answers