3. Power Supply
3.1. Supply Voltage
The Anybus CompactCom 40 PROFINET IRT requires a regulated 3.3 V power source as specified in the general
Anybus CompactCom 40 Hardware Design Guide.
3.2. Power Consumption
The Anybus CompactCom 40 PROFINET IRT is designed to fulfil the requirements of a Class B module. The current
hardware design consumes up to 390 mA.
The Anybus CompactCom 40 PROFINET IRT FO is designed to fulfil the requirements of a Class C module. The
current hardware design consumes up to 740 mA.
In line with HMS policy of continuous product development, we reserve the right to change the exact power
requirements of this product without prior notification. However, in any case, the Anybus CompactCom 40
PROFINET IO will remain as a Class B module.
4. Environmental Specification
Consult the Anybus CompactCom 40 Hardware Design Guide for further information.
5. EMC Compliance
Consult the Anybus CompactCom 40 Hardware Design Guide for further information.
6. Fiber Optics Compliance (MAU type Compliance)
The optical interface of the Anybus CompactCom 40 PROFINET IRT is compliant with the non IEEE802.3 MAU
type POF.
The supported cables are stated in the PI document PROFINET Cabling and Interconnection Technology;
for (SI-POF/PCF):
Physical Layer Medium Dependent Sublayer on 650 nm Fiber Optics
PROFIBUS & PROFINET International Order No: 2.432