Functional Safety Module Object (11h)
10.9.5. Instance Attributes (Instance #1)
#
Name
1
State
2
Vendor ID
3
IO Channel ID
4
Firmware version
5
Serial number
6
Output data
7
Input data
8
Error counters
9
Event log
10
Exception information
11
Bootloader version
12
Vendor block safe uc1
13
Vendor block safe uc2
SCM-1202-021 Version 2.6
Access
Data Type
Description
Get
UINT8
Current state of the Safety Module
Please consult the manual for the Safety Module used.
Get
UINT16
Identifies vendor of the Safety Module.
E.g. 0001h (HMS Industrial Networks)
Please consult the manual for the Safety Module used.
Get
UINT16
Describes the IO Channels that the Safety Module is equipped with.
Please consult the manual for the Safety Module used.
Get
Struct of
Safety Module firmware version.
UINT8 (Major)
Format: version "2.18.3" would be represented as: first byte = 0x02,
second byte = 0x12, third byte = 0x03.
UINT8 (Minor)
UINT8 (Build)
Get
UINT32
32 bit number, assigned to the Safety Module at production.
Please consult the manual for the Safety Module used.
Get
Array of UINT8
Current value of the Safety Module output data, i.e. data FROM the
network.
Get
Array of UINT8
Current value of the Safety Module input data, i.e. data sent TO the
network.
Get
Struct of
Error counters (each counter stops counting at FFFFh)
UINT16 (ABCC DR)
ABCC DR:
UINT16 (ABCC SE)
UINT16 (SM DR)
ABCC SE:
UINT16 (SM SE)
SM DR:
SM SE:
Get
Array of UINT8
Latest Safety Module event information (if any) is logged to this
attribute. Any older event information is erased when a new event is
logged.
For evaluation by HMS support.
Get
UINT8
If the Exception Code in the Anybus object is set to "Safety
communication error" (09h), additional exception information is
presented here, see table below.
Get
Struct of UINT8
Safety Module bootloader version.
Major UINT8 Minor
Format: version "2.12" would be represented as: first byte = 0x02,
second byte = 0x0C
Get
Array of UINT8
The Safety Module may supply additional vendor-specific data to the
Anybus CompactCom. If such data is available it is presented in this
attribute.
Get
Array of UINT8
The Safety Module may supply additional vendor-specific data to the
Anybus CompactCom. If such data is available it is presented in this
attribute.
®
™
Anybus
CompactCom
40 - PROFINET IRT Transparent
NOTE
This data is unsafe, since it is provided by the
Anybus CompactCom module.
NOTE
This data is unsafe, since it is provided by the
Anybus CompactCom module.
Responses (unexpected) from the
Safety Module, discarded by the
Anybus CompactCom module.
Serial reception errors detected by the
Anybus CompactCom module.
Responses (unexpected) from the
Anybus CompactCom module,
discarded by the Safety Module.
Serial reception errors detected by the
Safety Module.
Ethernet
Page 77 of 177
Need help?
Do you have a question about the Anybus CompactCom 40 and is the answer not in the manual?
Questions and answers