Anybus
CompactCom
40 - PROFINET IRT Transparent
Ethernet
Further Actions to Resolve Mismatch
If the mismatch remains unsolved, either for default or custom configuration, the following will be performed by
the Anybus CompactCom 40 PROFINET IRT to find a solution that will make exchange of valid data possible:
Incomplete output mapping:
Incomplete input mapping:
Mismatch of submodule(s):
See also...
• The Remap_ADI_Write_Area and Remap_ADI_Read_Area commands in the Application Data Object (FEh),
found in Anybus CompactCom 40 Software Design Guide.
Page 18 of 177
If the controller tries to connect to fewer output submodules than are plugged by the application,
the controller will not be granted ownership of any output submodule. The Anybus state is set to
ERROR and the LEDs will indicate configuration mismatch. Matching input submodules will be owned
by controller and work normally.
The controller may choose to connect to a subset of the available input submodules without any
restrictions. Anybus state is set to PROCESS_ACTIVE and no error is indicated on any LED.
As long as all of the output submodules of the Real Identification are present and matching in the
Expected Identification, the Anybus state is set to PROCESS_ACTIVE. However, if there is any mismatch
among the other submodules the LEDs will indicate configuration mismatch.
Real Identification (RI)
SCM-1202-021 Version 2.6