Download Print this page

HMS Networks Anybus CompactCom 40 Network Manual page 78

Profinet irt transparent ethernet
Hide thumbs Also See for Anybus CompactCom 40:

Advertisement

®
Anybus
CompactCom
40 - PROFINET IRT Transparent
Ethernet
10.8.12. Command Details: Appl_State_Ready
Category
Extended
Details
Command Code:
15h
Valid For:
Object Instance
Description
This command is only applicable if the host application implements support for End_Of_Prm_Ind, and signals to
the module (and in turn the I/O Controller) that the host application is ready for data exchange.
• Command Details
Field
Contents
CmdExt[0]
AR handle (low byte)
CmdExt[1]
AR handle (high byte)
See also...
Application Process Instances (API) (page 12)
– End_Of_Prm_Ind, command details in
10.8.13. Command Details: AR_Abort
Category
Extended
Details
Command Code:
16h
Valid For:
Object Instance
Description
This command indicates to the module that the current application relationship shall be aborted.
• Command Details
Field
Contents
CmdExt[0]
AR handle (low byte)
CmdExt[1]
AR handle (high byte)
See also...
Application Process Instances (API) (page 12)
– AR_Check_Ind, command details in
– Expected_Ident_Ind, command details in
– Appl_State_Ready, command details in
Page 70 of 177
Comments
Handle for the Application Relationship (AR)
PROFINET IO Object (F6h) (page 112)
Comments
Handle for the Application Relationship (AR)
PROFINET IO Object (F6h) (page 112)
PROFINET IO Object (F6h) (page 112)
PROFINET IO Object (F6h) (page 112)
Network PROFINET IO Object (0Eh)
SCM-1202-021 Version 2.6

Advertisement

loading
Need help?

Need help?

Do you have a question about the Anybus CompactCom 40 and is the answer not in the manual?

Questions and answers