Replacing The Interlock Switch Assembly; Figure 6-12 Removing And Replacing The Interlock Switch Assembly - Sun Microsystems Sun Blade 1000 Service Manual

Hide thumbs Also See for Sun Blade 1000:
Table of Contents

Advertisement

FIGURE 6-12
6.4.2

Replacing the Interlock Switch Assembly

Caution – Use proper ESD grounding techniques when handling components. Wear
an antistatic wrist strap and use an antistatic mat. Store ESD-sensitive components in
antistatic bags before placing them on any surface.
1. Connect the combined cable assembly connectors to the interlock switch
terminators (
2. Press the detent tabs at either side of the interlock switch assembly while
positioning the switch into the chassis.
3. Continue to press the detent tabs and pull the interlock switch assembly until the
switch is properly seated.
4. Detach the antistatic wrist strap, replace the access panel, and power on the
workstation.
See Chapter 9.
6-20
Sun Blade 1000 and Sun Blade 2000 Service Manual • January 2002
Combined cable
assembly connectors
Removing and Replacing the Interlock Switch Assembly
).
FIGURE 6-12
Detent tab (2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunblade 2000

Table of Contents