C0D50: Duplex Horizontal Transport Motor Malfunction; C0E00: Main Erase Lamp's Failure To Turn On; C0F24: Aidc Sensor Contamination Correction Failure; C0F33: Abnormally Low T/C As Detected By Atdc Sensor - Minolta Di450 Service Manual

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

Code
Description
C0BC0
C0BC1
Paper folding mechanism
malfunction
C0BC2
C0BC3
C0BF0 Control system malfunc-
tion
C0D50 Duplex Horizontal Trans-
port Motor malfunction
C0E00 Main Erase Lamp's fail-
ure to turn ON
C0F24 AIDC Sensor contamina-
tion correction failure
C0F32 ATDC Sensor malfunc-
tion
C0F33 Abnormally low T/C as
detected by ATDC Sen-
sor
C10XX
Memory Board failure
C11XX
C12XX
C12CX Hard Disk Drive failure
C1300 Polygon Motor malfunc-
tion
C1326 ARMS interface failure
C1330 VD signal error
Detection Timing
See the relevant option service manual.
• The Main Erase Lamp Malfunction signal remains
LOW for a continuous 1-sec. period while the Main
Erase Lamp remains OFF.
• The Main Erase Lamp Malfunction signal remains
HIGH for a continuous 1-sec. period while the Main
Erase Lamp remains ON.
The output voltage from the AIDC Sensor Board does
not fall within the range of 0.9V to 1.1V even after the
contamination correction and variation adjustment
have been made.
• The output voltage from the ATDC Sensor remains
0.2V or less, or 4.5V or more, for a continuous 3-
sec. period after the Developing Unit Drive Motor
has been energized.
• The output voltage from the ATDC Sensor does not
fall within the range of 2.45V to 2.55V during an F8
operation.
A T/C of 2.5% or less (ATDC Sensor output being
2.86V or more) is detected.
• No Lock signals are detected for the period of 5 to
20 sec. after the motor has started turning after the
Power Switch was turned ON.
• No Lock signals are detected for the period of 5 to
20 sec. after the motor has started turning at full
speed after the Start key was pressed.
• The Lock signal remains HIGH for a continuous
period of 3 sec. or more while the motor is running
at steady speed.
No answer is received within 1.5 sec. to a report trans-
mitted by the engine.
A LOW VD signal is not detected even after the lapse
of 60 sec. after an IDREQ signal has been output.
T-34