(5)
Registration (CD)
Requirement
Specification
5.0 ± 0.5 mm
This adjustment must be made after the PH Unit has been replaced.
Adjustment Procedure
1. Call the Adjust mode to the screen.
2. Touch [Printer].
3. Touch [Registration (CD)].
4. Select the paper source to be checked and adjusted.
5. Press the Start Key to let the copier produce a test pattern.
6. Check to see if width A on the test pattern is up to the specifications. If it is outside the
specified range, perform the following adjustment steps.
Width A on the test pattern output should fall within the
following range.
1155D154AB
Adjust Mode
Registration (CD)
D-89
Setting Range
-8.2 to +8.2