(19) C0F24: AIDC Sensor contamination correction failure
AIDC Sensor Board (PWB-G)
PWB-G
AIDC
C0F24
Step
1
PJ7A, CN10, and CN41 are plugged securely
into Master Board.
2
Photosensor/LED of the AIDC Sensor are con-
taminated.
Relevant Electrical Parts
Master Board (PWB-A)
CN10
CN41
1
1
1
3
10
10
2
2
11
11
3
1
12
12
24
24
Check
T-65
PWB-A
PJ7A-5B(AIDC LED)
PJ7A-6B(GND)
PJ7A-7B(AIDC OUT)
4002C21TAA
Result
Action
NO
Plug them in securely.
YES
Clean.
NO
Change AIDC Sensor
Board.
Change Master Board.