Smear On Back; Uneven Image Density; Gradation Reproduction Failure - Minolta Di450 Service Manual

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

(10) Smear on back

Section
Step
1
Suction Belts are dirty.
2
Image Transfer Corona is dirty.
3
Image Transfer Guide Plate is
dirty.
Engine
4
Pre-Fusing Guide Plate is
dirty.
5
Fusing Rollers are dirty.
6
Toner spilled over area inside
copier.

(11) Uneven image density

Section
Step
1
PC Drum is properly
grounded.
2
Comb Electrode and grid
mesh are dirty or deteriorated.
Engine
3
Image Transfer Corona is dirty
or deteriorated.
4
Toner is even on Sleeve/Mag-
net Roller.
1
Mirrors and lens are dirty.
IR
2
Exposure Lamp is dirty or
deteriorated.

(12) Gradation reproduction failure

Section
Step
1
Wiring between PH Unit and
Engine
Image Processing Board is
connected.
1
Shading sheet is dirty.
2
Wiring between CCD Assy
IR
and Image Processing Board
is connected.
Check
Result
YES Clean.
YES Clean.
NO
YES Clean.
YES Clean or change.
YES Clean.
Check
Result
NO
YES Clean or change.
YES Change.
NO
YES Clean.
YES Clean or change.
Check
Result
YES Change PH Unit.
YES Clean.
YES Change CCD Assy.
NO
T-77
Action
Clean.
Action
Clean or change PC Drum
ground plate.
Adjust DB. (See ADJUST-
MENT.) Correct developer
conveying mechanism.
Action
Change Image Processing
Board.
Change Image Processing
Board.
Connect.