Rev. 1.1/10.00
4. Referring to the adjusting gauge, move the
Upper Guide Plate Assy. as follows.
If the margin B is greater than the
specifications, move the Upper Guide Plate
Assy. toward left as needed.
If the margin B is greater than the
specifications, move the Upper Guide Plate
Assy. toward right as needed.
5. Loosen the screw as shown and then re-
tighten it.
6. Make a test print again and check for correct
registration.
7. Remount the Cover and close the Duplex
Unit.