Minolta Di450 Service Manual page 256

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

Touch Panel
Display
Toner Empty Stop Select whether or not to inhibit copying when a toner-empty condition
is detected.
T/C Abnormal
Select whether to enable or disable copying when an abnormal T/C is
detected.
Fusing (°C) Input
Set the temperature for fusing temperature control according to the
operating environment and the type of paper used.
T/C Auto Recover Select whether to enable or disable auto recovery of T/C when it
drops.
Controller Type
Set the type of the Printer Controller.
After the setting has been made, touch "END" and turn OFF and
ON the Power Switch.
Main. Sw notice
Select the timing at which the Printer Controller power is turned ON.
After the setting has been made, touch "END" and turn OFF and
ON the Power Switch.
Printer Time-Out
Set the timeout period for the printer.
After the setting has been made, touch "END" and turn OFF and
ON the Power Switch.
Warning Level
Select the type of warning display given when an error occurs in the
Printer Controller.
After the setting has been made, touch "END" and turn OFF and
ON the Power Switch.
Setting (The default is
Enable
Enable
1
180 °C
Enable
After the machine has completed its initial opera-
Mode 1
tion.
Mode 2
When the machine is turned ON.
Disable
Trouble
S-25
Highlighted
Disable
Disable
2
190 °C
Disable
0 to 9 (
0
)
1 to 99 (
Attention
).
3
195 °C
)
10 min.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di550

Table of Contents