(17) Disassembly of the Multi Bypass Unit

5. Remove four Suction Belts.
4002D085AB
6. Remove the Suction Roller as shown on the left.
4002D086AB
1. Remove the Right Door.
2. Remove four screws and the Separator Guide
Plate Assy.
4002D087AB
3. Remove the Spring.
NOTE
When reinstalling the Spring, place it so that its close-
coiled end faces the Separator Unit.
4002D088AB
4. Snap off the C-clip and remove the Separator Assy.
4002D089AB