14. Call the Tech. Rep. mode to the screen.
15. Touch [I.R. (EDH) Check].
16. Touch [Tech. Rep. Choice].
17. Touch [Erasure Width].
18. Press the Clear key to clear the current
setting value.
19. Use the 10-key pad to change the setting
value.
20. Touch [END] to validate the setting value.
21. Go back to the Basic screen.
22. Make another sample copy for rechecking.
If a shadow from the Original Scale is produced, try another setting value and check
again.
If no shadow is produced, return Lead Edge Erase to the value which has been
recorded.
11. Place a sheet of A3 or 11 × 17 paper on the Origi-
nal Glass and lower the Original Cover.
12. Make a copy in the full size (× 1.000) mode.
13. Check to see if a shadow of the Original Scale is
produced on the sample copy.
If no shadow is produced, return Lead Edge Erase
to the value which has been recorded.