Removal Of The Ir Unit - Minolta Di450 Service Manual

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

(4)

Removal of the IR Unit

1. Swing down the Front Door and slide out the Developer Unit.
2. Remove the Right Door, Left Door, Rear Upper Cover, Rear Cover and Control Panel.
3. Slide out the Fusing Unit.
4. Remove four screws and the Cover.
NOTE
Do not remove the belt mounting screw on the cover.
4002D196AC
5. Unplug two connectors, remove four screws and
remove the Main Hopper Unit.
4002D032AD
6. Remove three screws and the PH Cooling Fan
Motor mounting bracket Assy.
7. Remove six screws and the mounting bracket.
4002D046AB
8. Remove the Original Grass and EDH Glass.
9. Remove eight screws and the CCD Unit Cover.
4002D043AB
10. Remove four screws and the Cover.
4002D033AB
D-17