C0500, C0510
Step
1
Upper Fusing Roller Heater Lamp turns ON
when the Power Switch is turned ON.
2
Lower Fusing Roller Heater Lamp turns ON
when the malfunction is reset with the surface
temperature of Lower Fusing Roller Heater
Lamp is 140°C or less as indicated on "Level
History" under the Tech. Rep. mode.
3
Upper and Lower Fusing Roller Thermistors
are installed properly.
4
Upper and Lower Fusing Roller Thermistors
are dirty.
5
Upper Fusing Roller Thermistor operation: the
resistance across CN217-2 and 3 on the Fus-
ing Unit end is infinity with CN217 (4P) discon-
nected.
6
Lower Fusing Roller Thermistor operation: the
resistance across CN218-2 and 3 on the Fus-
ing Unit end is infinity with CN218 (4P) discon-
nected.
7
Upper Fusing Roller Thermostat and Upper
Fusing Roller Heater Lamp continuity: there is
continuity across CN11-1 and 8 with CN11
(16P) disconnected.
8
Lower Fusing Roller Heater Lamp continuity:
there is continuity across CN11-9 and 16 with
CN11 (16P) disconnected.
Check
T-49
Result
Action
YES
Correct thermistor for
mounting position and/or
clean.
NO
Check step 7 and onward.
NO
Reinstall.
NO
Clean.
YES
Change Upper Fusing
Roller Thermistor.
YES
Change Lower Fusing
Roller Thermistor.
NO
Change thermostat and
heater lamp.
NO
Change heater lamp.