Minolta Di450 Service Manual page 451

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

C004F
Step
1
Power Supply Unit Cooling Fan Motor 2 rota-
tion: the voltage across PJ6A-11 on Power
Supply Board and GND is DC24V after the
malfunction has been reset.
2
Power Supply Unit Cooling Fan Motor 2 rota-
tion: the voltage across PJ6A-13 on Power
Supply Board and GND is DC5V after the mal-
function has been reset.
Check
T-43
Result
Action
NO
Change Master Board.
YES
Check motor for installa-
tion.
Change motor.
NO
Change Master Board.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di550

Table of Contents