C0045
Step
1
IR Cooling Fan Motor rotation: the voltage
across PJ4IC-4 on SCP Board and GND is
DC24V (during high-speed rotation) and
DC12V (during low-speed rotation) after the
malfunction has been reset.
2
IR Cooling Fan Motor rotation: the voltage
across PJ4IC-6 on SCP Board and GND is
DC5V after the malfunction has been reset.
C0046
Step
1
PH Cooling Fan Motor 1 rotation: the voltage
across PJ4IC-1 on Master Board and GND is
DC24V after the malfunction has been reset.
2
PH Cooling Fan Motor 1 rotation: the voltage
across PJ4IC-3 on Master Board and GND is
DC0V after the malfunction has been reset.
C0047
Step
1
PH Cooling Fan Motor 2 rotation: the voltage
across PJ4IC-7 on Master Board and GND is
DC24V after the malfunction has been reset.
2
PH Cooling Fan Motor 2 rotation: the voltage
across PJ4IC-9 on Master Board and GND is
DC0V after the malfunction has been reset.
Check
Check
Check
T-40
Result
Action
NO
Change SCP Board.
YES
Change SCP Board.
NO
Check motor for installa-
tion.
Change motor.
Result
Action
NO
Change SCP Board.
YES
Change SCP Board.
NO
Check motor for installa-
tion.
Change motor.
Result
Action
NO
Change SCP Board.
YES
Change SCP Board.
NO
Check motor for installa-
tion.
Change motor.