Removal of the Image Transfer Corona Wire

(8)

Cleaning of the Paper Separator Corona Wire

1. Remove the End Caps from the front and rear ends
of the Unit.
4002D149AA
2. Remove the corona wire, first at the spring end.
4002D150AA
1. Remove the four Paper Guides.
4002D151AA
2. Dampen a soft cloth with alcohol, hold it with a pair
of tweezers, and wipe the Paper Separator Corona
Wire gently in one direction.
NOTE
Wipe the wire from the hook to spring end.
1136D203AA