Removal of the PH Unit

NOTES
• Do not place the PH Unit upside down, tilt it excessively, or subject it to excessive shock.
• Replace the PH Unit as one unit.
• NEVER attempt to disassemble or adjust the PH Unit.
• Whenever the PH Unit has been removed, make the following adjustments:
Lead/Trail Edge Erase and Registration (CD/FD).
22. Remove the IR Unit.
4002D042AB
1. Remove the Right Cover.
2. Remove the Original Glass and EDH Glass.
3. Remove eight screws and the CCD Unit Cover.
4002D043AB
4. Remove three screws and the cover.
4002D260AA
5. Unplug two connectors, two flat cables.
6. Remove the harness from the edge cover.
4002D045AB
D-20