Goodrive3000 series medium voltage VFD
Function
code
P01.23
After a VFD running command is given, the VFD is in standby state and restarts with the delay defined by P01.23 to
implement brake release.
Function
code
P01.24
The function code is used to set the delay time of stop speed of the VFD. When the actual output frequency of the VFD is
equal to P01.15 and it lasts over the time set by P01.24, the VFD will stop.
Function
code
P01.25
0Hz output selection
The function code is used to select the output type of the VFD at 0Hz.
P02 group––Parameters of motor 1
Function
code
P02.00
The function code is used to select the type of motor 1.
Function
code
P02.01
Rated power of AM 1 0.1–3000.0kW
Rated frequency of
P02.02
P02.03
Rated speed of AM 1 1–36000rpm
Output frequency
Running
Name
Start delay
0.0–60.0s
Name
Stop speed delay
0.0–100.0s
Stop
speed
Name
0: Output without voltage
1: Output with voltage
2: Output with the DC braking current
for stop
Name
0: Asynchronous motor (AM)
Type of motor 1
1: Synchronous motor (SM)
Name
0.01Hz–P00.03 (Max. output
AM 1
frequency)
t1=P01.22
t2=P01.23
t1
t2
Running
Power off
Power on
Description
Description
Output frequency
P01.24
running
Description
Description
Description
-69-
Goodrive3000 inverter
t
Setting range
0.0–60.0
Setting range
0.0–100.0
T
Setting range
0–2
Setting range
0–1
Setting range
0.1–3000.0
depended
0.01–P00.03
1–36000
depended
Default
0.0s
Default
0.0s
Default
0
Default
0
Default
Model
50.00Hz
Model