Goodrive3000 series medium voltage VFD
LED No.

9.6 Related function codes

Related function codes for rectifier unit
Function
code
P12.00
Module type
P12.01
Module address
P12.02
Received PZD2
P12.03
Received PZD3
P12.04
Received PZD4
P12.05
Received PZD5
P12.06
Received PZD6
P12.07
Received PZD7
P12.08
Received PZD8
P12.09
Received PZD9
P12.10
Received PZD10
P12.11
Received PZD11
P12.12
Received PZD12
P12.13
Sent PZD2
P12.14
Sent PZD3
P12.15
Sent PZD4
P12.16
Sent PZD5
P12.17
Sent PZD6
P12.18
Sent PZD7
P12.19
Sent PZD8
P12.20
Sent PZD9
P12.21
Sent PZD10
P12.22
Sent PZD11
P12.23
Sent PZD12
Temporary variable 1
P12.24
for PZD sending
Name
Color
The length of the user parameter data set during the module
initialization is different from that during the network configuration.
It blinks at the frequency of 2 Hz when user parameter data is
incorrect: The length or content of the user parameter data set during
the module initialization is different from that during the network
configuration.
It blinks at the frequency of 4 Hz when an error occurs in the ASIC
initialization of communication.
Name
0: PROFIBUS
0–127
0: Disable
1: DC voltage setting (0–40000; Unit: 0.1V)
2–4: Reserved
5: AO setting 1
(-1000–1000, 1000 corresponding to 100.0%)
6: AO setting 2
(-1000–1000, 1000 corresponding to 100.0%)
7–13: Reserved
0: Disable
1: DC voltage (* 10, V)
2: DC voltage feedback (* 10, V)
3: Input voltage valid value (* 10, V)
4: Input current valid value (* 10, A)
5: Input power (* 10, kW)
6: Input power factor (*100)
7: Grid frequency (* 10, Hz)
8: Active current feedback (100% corresponds to
the rectifier rated current.)
9: Reactive current feedback (100% corresponds
to the rectifier rated current.)
10: Fault code
11: AI1 input (*100, V)
12: AI2 input (*100, V)
13: AI3 input (* 100, V)
14: Terminal input status
15: Terminal output status
16: Running status word
17–20: Reserved
0–65535
Function
Description
-225-
PROFIBUS communication
Setting
Default
range
0
0
0–127
2
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–13
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–20
0
0–65535