Goodrive3000 series medium voltage VFD
Function
code
protection voltage
P11.05
Current limit mode
Automatic current limit
P11.06
Frequency drop rate during
P11.07
Pre-alarm selection for
P11.08
VFD/motor OL/UL
Overload pre-alarm
P11.09
detection threshold
Overload pre-alarm
P11.10
Underload pre-alarm
P11.11
detection threshold
Underload pre-alarm
P11.12
Fault output terminal action
P11.13
upon fault occurring
Name
voltage)
0x00–0x11
Ones place: Current limit action
0: Invalid
1: Always valid
Tens place: Hardware current
limit overload alarm
0: Valid
1: Invalid
50.0–200.0%
threshold
0.00–50.00Hz/s
current limit
0x000–0x131
Ones place:
0:
relative
current.
1: VFD OL/UL pre-alarm, relative
to the VFD rated current
Tens place:
0: The VFD continues to work for
an OL/UL alarm.
1: The VFD continues to work for
a UL alarm but stops running for
an OL fault.
2: The VFD continues to work for
an OL alarm but stops running
for a UL fault.
3. The VFD stops running for an
OL/UL alarm.
Hundreds place:
0: Detect all the time.
1: Detect during constant speed
running.
P11.11–200%
0.1–60.0s
detection time
0%– P11.09
0.1–60.0s
detection time
0x00–0x11
Ones place:
0: Act upon an undervoltage fault
1:
undervoltage fault
Description
Motor
OL/UL
pre-alarm,
to
the
rated
motor
Do
not
act
upon
-175-
Goodrive3000 inverter
Setting
Default Modify
range
0x00–0x11
0x01
50.0–200.0
150.0%
0.00–50.00 10.00Hz/s
0x000–
0x000
0x131
P11.11–200
150%
0.1–60.0
1.0s
0–P11.09
50%
0.1–60.0
1.0s
0x00–0x11
0x00
an