Figure 2-14
R into A and R into B Crosstalk Test Setup
2. Press
Preset
Power
AVERAGING ON IF BW
3. Press
Scale Ref
4. Press
Marker Search
5. Press
Stop
1
.
x1
6. When the analyzer finishes the number of sweeps, write the marker value, which
appears on the analyzer display, on the performance test record.
R into A Crosstalk from 1 GHz to 3 GHz
7. Press
Start
1
8. When the analyzer finishes the number of sweeps, write the marker value, which
appears on the analyzer display, on the performance test record.
(Only for Option 006 Analyzers) R into A Crosstalk from 3 GHz to 4.5 GHz
9. Press
Start
3
10.When the analyzer finishes the number of sweeps, write the marker value, which
appears on the analyzer display, on the performance test record.
(Only for Option 006 Analyzers) R into A Crosstalk from 4.5 GHz to 6 GHz
11.Press
Start
4.5
12.When the analyzer finishes the number of sweeps, write the marker value, which
appears on the analyzer display, on the performance test record.
R into B Crosstalk from 300 kHz to 1 GHz
13.Press
Start
300
Chapter 2
6
x1
Avg
.
10
x1
to get a better scaling of the data trace.
25
x1
TRACKING ON
G/n
Sweep Setup
G/n
Stop
3
G/n
G/n
Stop
4.5
G/n
G/n
Stop
6
k/m
Stop
1
AVERAGING FACTOR
.
SEARCH:MAX
TRIGGER MENU
NUMBER of GROUPS
NUMBER of GROUPS
NUMBER of GROUPS
NUMBER of GROUPS
G/n
.
G/n
Performance Tests
9. Receiver Input Crosstalk
5
x1
5
.
5
x1
.
5
x1
.
5
x1
2-33