Lm - Motor Data Parameters - KEB COMBIVERT F5 Reference Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

6.3 LM - Motor Data Parameters

LM01
Motor Power
LM - Motor Data Parameters
These parameters define and display all relevant motor values and motor
protection settings. The drive will only allow access to motor parameters
related to the motor loaded in US03.
Parameters that pertain to induction motors will have the following icon listed
beside it.
Parameters that pertain to permanent magnet motors will have the following
icon listed beside it.
The rated power of the motor, according to nameplate. The unit will be either
HP or kW, according to the US02 System Units setting.
Conversion:
• 1 kW = 1.36 HP
• 1 HP = 0.735 kW
For induction motors, enter the nameplate motor power
For PM Synchronous Motors, the rated power is calculated from the rated
motor speed (LM02) and rated motor torque (LM07) and is therefore read-
only. Refer to LM07 Motor Torque for further details.