KEB COMBIVERT F5 Reference Manual page 333

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Errata
Section 6.16: Added DG78 Direction Change Counter. Corrected DG19 parameter
set table to include 0=Idle and change Pretorque to =1.
Fault Tables: Corrected the E.OP section describing the GTR7 turn on voltage; this
was changed erroneously to 780VDC for 400V units - it should be 760VDC.
(v3.31) Rev1A Corrections
SD Card Keypad: 00F5060-K000 keypad with SD card port is not used with 3.31;
all references to the SD card keypad have been removed.
TTL Incremental Terminal Strip - Encoder Connections: Updated the wiring
instruction for encoders with no zero channel - the N-(X3A.6) can be connected to
0V common X3B.8 as well as X3A.8 - both are 0V common.
Initial Startup: Corrected the timing chart; Drive On turns off when LT12 expires.
The previous chart had it turning off when LT13 expires. The correction was also
applied to the charts in Sections 6.9 and 6.14.
Replacement Parts: Updated encoder card part#'s - 2MF5K81-BZ05 changed to
2MF5K81-BY05 and 2MF5K8G-PZ33 changed to 2MF5K8G-PY33
Section 4.9: Setting date and time description corrected; The date/time can be
initialized by going to home>prog>setup>date/time, select and press enter, set the
date/time and press enter to save.
Section 6.1: Added CAN Open lift functionality to the list of control type options.
Section 6.2: Added Braking Transistor On functionality to the list of digital input
functions. Added LI50 UPS Mode (Easy Direction).
Section 6.4: LE07 Rotor Detection function updated to include more power on /
reset options.
Section 6.6: Added LS00 Zero Speed Offset to speed profile parameters.
Section 6.8: Added parameters LC35 No Load Torque and LC36 Full Load Torque
to control settings parameters. LC13 description corrected; Corner speed at which
(not below) the acceleration integral offset (LC11) is fully added. LC15 description
corrected; Corner speed at which (not below) the deceleration integral offset
(LC12) is fully added. LC16 description corrected; Corner speed at which only the
deceleration integral gain is active (no deceleration integral offset added) - (not
acceleration integral offset added).
Section 6.11: Added LX25 Unintended Motion Distance and LX07 Carrier Frequency
Handling to special functions parameters. Section 6.13: Added parameters LA50
Analog 1 Interface Selection, LA60 Analog 2 Interface Selection.
Section 6.16: Added DG58 Car Load and DG99 Last Fault to diagnostic parameters.
Section 7.2: Speed Selection Error description corrected; binary and serial binary
modes added as they were not included in the description. Unintended Movement
description updated to reflect the addition of LX25. Encoder slippage description
corrected - in reference to a pole position count that is more than 4000 off; this was
changed to 2000 as this value is referenced elsewhere in the manual. Section 7.2:
Modulation Grade Limit Reached description corrected; in reference to LM22, the
lower limit of the parameter should be around 45%. Analog Signal Failure description
corrected - Serial Serv. 49 and 50 were missing from the text.
Section 8.1: Updated parameter reference table with new parameters LX25, LA50,
333