KEB COMBIVERT F5 Reference Manual page 124

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

LI - Input Parameters
124
Binary Speed Selection
Utilizes three binary-coded inputs for up to 7 speeds.
Older KEB elevator software and worldwide variants are available. Because of
this, several different truth tables for the Binary Speed selection are available:
Versions:
US Lift
1.60, 1.62, 1.72 B(Level - Correction - Inspection)
US Lift
1.51, 1.61, 1.71 B(Inspection - Level - Correction)
Euro Lift
1.00, 2.20
-
The following are the corresponding logic tables. Although inputs I2...I4 are
shown, the inputs actually used for speed selection are configurable and
can be defined in LI04-11. Refer to Section 3.1.1 or 3.2.2 for input terminal
assignments.
Custom binary table selections can be created with LI16 Custom Input
i
Decoding.
LI03 = B(Level - Correction - Inspection), NUM = 0
US04
Binary Speed
Selection
S
Z
ERO
S
L
EVELING
S
H
IGH
S
I
NSPECTION
S
C
ORRECTION
S
I
NTERMEDIATE
S
I
NTERMEDIATE
S
I
NTERMEDIATE
Symbol:
LI03 Setting:
B(Level - Correction - High)
-
LI16 Custom Input Decoding
Parameter
-
LS01
LS02
LS03
LS04
LS05
1
LS06
2
LS07
3
1
=
Input is active
0
=
Input is not active
Control Inputs
I2
I3
I4
0
0
0
1
0
0
0
0
1
1
1
0
0
1
0
1
0
1
0
1
1
1
1
1
NUM
0
1
2
3

Hide quick links: