KEB COMBIVERT F5 Reference Manual page 322

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Parameter Reference
Para.
Name
DG50
Elevator Speed
DG51
Mode
DG52
Active Profile
DG53
Active Speed
DG54
Leveling Distance
DG55
Target Floor
DG56
Current Floor
DG57
Next Avail. Floor
DG58
Car Load
DG59
Brake Release Time
DG60
Average Regen Power
DG61
Peak Regen Power
DG62
Runs Per Hour
DG63
NTSD Speed 1 Up
DG64
NTSD Speed 2 Up
DG65
NTSD Speed 3 Up
DG66
NTSD Speed 1 Down
DG67
NTSD Speed 2 Down
DG68
NTSD Speed 3 Down
DG69
Total Runs
DG70
Calculated Motor Pole
DG71
Encoder Deviation
DG72
Actual Position
DG73
Lift App Control Word
DG75
Motor Speed (Calculated)
Elevator Speed
DG76
(Calculated)
Signed Elevator Speed
DG77
(Calculated)
DG78
Direction Change Counter
DG79
Suggested UPS Direction
DG93
Fault Log (Count)
DG94
Fault Log (Timestamp)
DG99
Last Fault
DB00
Lift Time
DB01
DIN/Switch/ServSLV Time
DB02
Lift Com Time
FB01
Field Bus Control Word
322
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Hex
v1.72
Motor/Gear Type
I
IX
P
PX
11B2h
LF90
RO
RO
RO
RO
11B3h
RO
RO
RO
RO
11B4h
RO
RO
RO
RO
11B5h
RO
RO
RO
RO
11B6h
RO
RO
RO
RO
11B7h
RO
RO
RO
RO
11B8h
RO
RO
RO
RO
11B9h
RO
RO
RO
RO
11BAh
RO
RO
RO
RO
11BBh
RO
RO
RO
RO
11BCh
RO
RO
RO
RO
11BDh
RO
RO
RO
RO
11BEh
RO
RO
RO
RO
11BFh
RO
RO
RO
RO
11C0h
RO
RO
RO
RO
11C1h
RO
RO
RO
RO
11C2h
RO
RO
RO
RO
11C3h
RO
RO
RO
RO
11C4h
RO
RO
RO
RO
11C5h
RO
RO
RO
RO
11C6h
RO
RO
RO
RO
11C7h
RO
RO
RO
RO
11C8h
RO
RO
RO
RO
11C9h
RO
RO
RO
RO
11CBh
RO
RO
RO
RO
11CCh
RO
RO
RO
RO
11CDh
RO
RO
RO
RO
11CEh
RO
RO
RO
RO
11CFh
RO
RO
RO
RO
11DDh
RO
RO
RO
RO
11DEh
RO
RO
RO
RO
11E3h
RO
RO
RO
RO
-
-
-
1281
RO
RO
RO
RO
Setting
NUM
Options
-
-
See Section 6.16
-
None
0
Inspection
1
High Speed
2
One Floor
4
Emergency
8
Correction
16
Emergency Slowdown
32
None
0
Inspection Speed
32
Leveling Speed
64
Correction Speed
96
High Speed
128
Intermediate Speed 1
160
Earthquake Speed
256
Intermediate Speed 2
384
Emergency Generator Speed
512
Intermediate Speed 3
640
UPS Speed
768
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Range
Units
Min.
Max.
Imp.
Met.
0
2000
ft/min
0.000
10.160
-
m/s
0
65535
-
0
65535
-
0
65535
-
0.0
18.0
in
0.0
45.7
-
0
64
-
0
64
-
0
64
-
-100
100
%
0.00
5.00
sec
0.0
3000.0
kW
0.0
3000.0
kW
0
500
-
ft/min
m/s
ft/min
m/s
ft/min
m/s
ft/min
m/s
ft/min
m/s
ft/min
m/s
1/min
1/min
ft/min
m.s
ft/min
m/s
-
-
-
-
-
-
-
-
0h
FFFFh
-
Pass
Default
Level
-
0
0.000
-
0
-
0
-
0
-
0.0
cm
0.0
-
0
-
0
-
0
0
0.00
0.0
0.0
-
0
-
-
-
-
-
-
0
-
-
0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
OEM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents