KEB COMBIVERT F5 Reference Manual page 154

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

LM - Motor Data Parameters
LM26
Motor Ls Max
LM27
Motor Inductance
Mode
154
This parameter is not applicable to Induction motors and therefore will not
appear.
Maximum motor inductance.
This value can be learned with a Motor Tune. Refer to Section 5.9 for
i
further details.
This parameter is not applicable to Induction motors and therefore will not
appear.
This parameter selects the relationship between the motor rated and maximum
inductances. It is determined by the drive and is used as part of the LL05 SPI
function. If the LM01 Motor Tune has been completed, this parameter should
not need adjustment and is only available for advanced troubleshooting.
Settings:
Ld <> Lq
Ld = Lq
Default = Ld <> Lq (0)
This value can be learned with a Motor Tune. Refer to Section 5.9 for
i
further details.
NUM
0
1