LE13
UVW Encoder
Commutation
LE14
Serial Encoder 1
Selection
LE15
PT1 Time Encoder 1
LE16
SSi Data Format
LE17
SSi Data Resolution
The number of commutation poles for a UVW encoder. In general, the number
of UVW encoder and motor poles should be the same; if different, it is possible
to adjust the number of UVW encoder poles. This parameter is only relevant
when the encoder type is UVW and a UVW encoder feedback is interface
is used (LE01 = UVW Interface).
Default = '= motor pairs of poles' (NUM = 0)
The type of encoder serial protocol. This parameter is only functioning
when the BiSS/EnDat 2.2 encoder interface card is installed.
Settings:
EnDat 2.2
BiSS Hengstler Acuro
BiSS C-Mode
Default = EnDat 2.2 (0)
Low pass filter on speed of the measured speed value.
Sets the data format of the SSi transmission between encoder and inverter.
This parameter is only relevant when the encoder type is SSi and an SSi
feedback interface is used (LE01 = SSi-SIN/COS).
Settings:
Binary
Gray Scale
Default = Binary (0)
Sets the resolution of the data of the SSI transmission. This parameter is only
relevant when the encoder type is SSi and an SSi feedback interface is
used (LE01 = SSi-SIN/COS).