LS - Speed Profile Parameters
LS30
Acceleration One Floor
LS31
Start Jerk One Floor
LS32
Acceleration Jerk One
Floor
LS33
Deceleration One Floor
NTS
LS34
Deceleration Jerk One
Floor NTS
LS35
Stop Jerk One Floor
NTS
LS37
Intermediate Speed 1
Correction
LS38
Intermediate Speed 2
Correction
174
One Floor (Intermediate 1, 2) and NTS Speed Profile Rate Settings
Acceleration rate for One Floor profile (Intermediate Speed 1 or 2).
Start Jerk rate into acceleration for One Floor Speed profile (Intermediate
Speed 1 or 2).
Acceleration Jerk rate into intermediate speed for One Floor Speed profile
(Intermediate Speed 1 or 2).
Deceleration rate for One Floor Speed profile (Intermediate Speed 1 or 2), or
when NTS Slowdown Function is activated.
Jerk rate out of intermediate speed into deceleration for One Floor Speed profile
(Intermediate Speed 1 or 2), or when NTS Slowdown function is activated.
Jerk rate out of deceleration into leveling speed for One Floor Speed profile
(Intermediate Speed 1 or 2), or into TS02 NTSD Target Speed when NTS
Slowdown function is activated.
The amount of leveling distance to be eliminated from run at Intermediate
Speed 1. Refer to parameter LS27 for further description.
The amount of leveling distance to be eliminated from run at Intermediate
Speed 2. Refer to parameter LS27 for further description.