KEB COMBIVERT F5 Reference Manual page 310

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Parameter Reference
Para.
Name
LI04
Input 1 Function (I1)
LI05
Input 2 Function (I2)
LI06
Input 3 Function (I3)
LI07
Input 4 Function (I4)
LI08
Input 5 Function (I5)
LI09
Input 6 Function (I6)
LI11
Input 8 Function (I8)
LI15
Direction Selection Inputs
LI16
Custom Input Decoding
LI20
Brake Switch Function
LI50
UPS Mode
LI60
Correction is Inspection
LM01
Motor Power
LM02
Motor Speed
LM03
Motor Current
LM04
Motor Frequency
LM05
Motor Voltage
LM06
Motor Power Factor
310
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Hex
v1.72
Motor/Gear Type
I
IX
P
PX
0384
-
0385
-
0386
-
0387
-
0388
-
0389
-
038B
-
038F
-
0390
-
0394
-
03B2
-
03BC
0681
LF10
RO
RO
0682
LF11
0683
LF12
0684
LF13
0685
LF14
0686
LF15
Setting
NUM
Options
No Function*
0
UPS Operation*
1
Reduced Torque*
2
Emergency Profile*
4
Emergency Generator Speed*
8
Fault Reset
16
External Fault
17
Brake Release Confirm.
18
Main Contactor Check
19
Earthquake Speed
20
Emergency Slowdown (ESD)
21
Position Selection
22
Position Deviation Reset
23
Teach Value
24
Up Direction
25
Down Direction
26
Speed Selection
27
ETS (Emergency Terminal
28
Slowdown)
NTS1 (Normal Terminal Slowdown
29
NTS2
30
NTS3
31
Inspection Speed
32
Regen Fault
33
Braking Transistor On
34
125% NTS
35
*Can be selected together
Same as LI04
"
Same as LI04
"
Same as LI04
"
Same as LI04
"
Same as LI04
"
Same as LI04
"
Direction Selection
Up and Down Inputs
0
Down Input Only
1
Up & Down AND Serial Control
2
Word
Brake Function
Function by Direction Inputs
0
Function by Speed Selection
4
-
-
General Reset
0
3 Auto Resets
1
Forced Reset
2
Default
0
Easy Direction
1
Off
0
On
1
-
-
-
-
-
-
-
-
-
-
-
-
-
Range
Units
Min.
Max.
Imp.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
00000000h
-
-
-
-
-
-
-
-
-
0.5
299.5
HP
0.3
225
-
0.5
299.5
HP
0.3
225
-
20
4000
rpm
400
4000
-
20.0
500.0
400
4000
rpm
20.0
500.0
1.0
1000.0
Amps
4.0
200.0
Hz
4.0
200.0
-
4.0
200.0
Hz
10
32000
V
10
500
V
0.5
1.00
-
NA
NA
NA
Pass
Default
Level
Met.
-
No Function
OEM
-
No Function
OEM
-
No Function
OEM
-
No Function
OEM
-
No Function
OEM
-
No Function
OEM
-
No Function
OEM
(0); Up and
Down Inputs
-
+ Function
OEM
by Direction
Inputs
00000000h
OEM
General
-
OEM
Reset
-
Default
OEM
-
Off
OEM
-
10
kW
7.5
Basic
-
Calculated
kW
Calculated
-
1164
rpm
1450
Basic
100.0
1000
100.0
1.0
Basic
-
60.0
Hz
50.0
Basic
50.0
400
Basic
100
0.90
Basic
NA
NA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents