KEB COMBIVERT F5 Reference Manual page 274

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Diagnostics and Troubleshooting
Error/Message Alt. /
(NUM)
Error Encoder
EHyb
Card
(52)
Error Encoder
EHybC
Card Changed
(59)
Error Encoder
EENCC
Interface
(35)
Error External
EEF
Fault
(31)
Error HSP5
EBus
Serial Com.
(18)
(EBus)
274
*Additional information at end of section
Description
Cause/Solution/Troubleshoot
Invalid encoder
Check for correct encoder connections/pinout. Incorrect
interface identifier
pinout may drag the encoder board power supply down.
Check encoder card connection to control board for bent
or missing pins and proper connection.
Otherwise, the board may be defective and should be
replaced.
Indicates the
This error should automatically clear itself. If not, re-
encoder interface
Enter the read-only setting in parameter LE01.
card has been
changed.
Loss of encoder
This error should be accompanied with further
channel or
information describing the nature of the fault. Refer to
communication
LE12 Serial Encoder 1 Status for further details.
between encoder
and drive for an
absolute encoder.
A digital input can
The digital input for an External Fault may come from the
be programmed
controller or may be jumpered from an inverter or regen
to trigger an error.
digital output. The cause of the error will be variable.
Identify the source of the External Fault input and the
conditions which would trigger this input.
This message
Verify keypad operator is seated properly to the
indicates
inverter.
that serial
communication
between the
keypad operator
and the drive or
the drive and the
elevator control
has been lost
(See parameter
Verify serial comm. between controller and drive.
LX09 Ser.Com
Watchdog Time to
Verify connection of keypad operator and inverter control
bypass this fault).
card.
Verify connection of the serial comm. to the keypad
operator at port X6C.
Verify there are no bent or missing pins where the
serial comm. cable from the controller plugs into the
keypad operator.
Verify there are no bent or missing pins where the
keypad operator connects to the control card.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents