Incremental Ttl Encoder Interface X3A Subd - KEB COMBIVERT F5 Reference Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

TTL Incremental SubD - Encoder Connections
3.3.8 Incremental TTL
Encoder Interface X3A
SubD
72
Connect the incremental encoder mounted on the motor to the 15-pin
Sub-D connector at X3A. This connection provides speed feedback and is
imperative to the proper operation of the F5.
Encoder Card Part Number: Housing Size ≤ E, 1MF5K81-DZ19. Housing
Size ≥ G 2MF5K81-DZ19.
ONLY when the inverter is switched off and the voltage
supply is disconnected may the feedback connectors be
removed or connected!
5
4
3
10
9
8
15
14
13
The internal voltage of "V
an unregulated supply and will allow up
to 170 mA max. current draw, for X3A and
X3B total. If higher voltages/currents are
required, then an external power supply
must be provided.
The +5.2 V is a regulated voltage supply
generated from V
and will allow up to
var
500 mA max. current draw, for X3A and
X3B total. If additional current is required
from the +5.2 V output, the current from
V
decreases in accordance with the
var
following formula:
5.2 V x I
I
= 170 mA -
–————
var
The following specifications apply to encoder interface X3A and X3B, channel 1
and 2, respectively:
Max. operating frequency:
Internal terminating resistance:
RS422 or TTL level square wave
voltage level:
Input Wiring
A +
B +
approx.
34 Ω
A -
B -
2
1
7
6
12
11
" 24...30 V is
var
+5V
V
var
approx.
120 Ω
Pin No. Signal
3
A-
4
B-
8
A+
9
B+
11
V
24...30 V
var
12
+5.2 V
13
0V (com)
14
N-
15
N+
Shield
Housing
300 kHz.
R
= 120 Ω
t
2...5 Vdc

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents