DG - Diagnostics Parameters (Combivis only)
DG11
Output Status
DG16
Output Condition State
DG19
Parameter Set
DG50
Elevator Speed
parameter
256
The displayed numerical value is the sum of the individual output
weightings. For example, DG11 = 12 = Relay 1 (4) + Relay 2 (8).
Value:
0
1
2
4
8
The displayed numerical value is the sum of the individual output condition
weightings.
The Parameter Set indicates the state of the run sequence in the drive. This
diagnostic parameter only applies to control modes US04 Control Type =
Binary Speed Selection (1) and Digital Speed Selection (0).
Value: Description:
1
2
3
4
5
6
7
This shows the calculated elevator speed in either FPM or m/sec
Description:
None
Output 1
Output 2
Relay 1
Relay 2
Value: Description:
0
None
1
Condition 0
2
Condition 1
4
Condition 2
8
Condition 3
16
Condition 4
32
Condition 5
64
Condition 6
128
Condition 7
Pre-torque
Normal Acceleration
Normal Deceleration
One Floor Acceleration
One Floor Deceleration
Emergency Acceleration
Emergency Deceleration