Analog Outputs (F5-K); Sto Connections (F5-K) - KEB COMBIVERT F5 Reference Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

3.2.7 Analog outputs (F5-K)

3.2.8 STO Connections (F5-K)

Control Connections (Safety)
0...10Vdc
I
max=
Pin
Name
Description
1
STO1+
2
STO1+
Input STO Channel 1
3
STO1-
4
STO1-
5
STO2+
6
STO2+
Input STO Channel 2
7
STO2-
8
STO2-
9
STO-OUT
Output STO
10
STO-OUT
The individual channels are designed potential-free, so 24V and 0V can
be connected. The inputs are designed in a way that safety switchgear
units with test pulses (OSSD signals) can be connected. The signals are
not evaluated, they are only filtered. The OSSD test interval is limited to 10
ms.
10mA
2224
21
23
X2B - Safety Control
0...10Vdc
I
10mA
max=
49