US - Basic Setup Parameters
US05
Load Configuration
US06
Contract Speed
120
After entering the basic setup parameters (US02-US04 & US06) the system
configuration must be written to the drive. This procedure loads the drive with
the correct parameters depending on the motor type and sets the correct limits
and scalings.
Upon successful loading, US05 will display Configuration OK.
A user can also save/load OEM defaults and read/write to various memory
locations. These are the following options available in US05:
If the parameters US02 System Units, US03 Motor Type, or US04 Control Type
are changed, the configuration will need to be reloaded in US05 for changes
to take effect.
If the US03 Motor Type is changed, then a subsequent Write Configuration
to Drive will result in the defaulting of drive parameters.
This parameter sets the contract speed which serves as an upper speed limit
for normal operation.
i
In addition, an overspeed level is automatically set at 110% of this value.
Settings:
Not Configured
Configuration OK
Write Configuration to Drive
Read Configuration from Drive
Write Configuration to Flash
Read Configuration to Flash
Create OEM Default
Restore OEM Defaults
Restore KEB Defaults
NUM
0
1
2
3
4
5
8
9
10