Diagnostics and Troubleshooting

7.5 Learn Procedure Troubleshooting

Problem:
Unable to start learn procedure.
Unable to complete learn
procedure successfully
306
Troubleshoot:
Check input signals:
The Motor Tune, SPI, and the Encoder Pole Position Learn
only require the Drive Enable (I7) to begin (for serial speed
control modes, this includes the enable of the Control Word).
The Encoder Synchronization and Inertia Learn require a run
command (Drive Enable, Direction, and speed command).
If 'Measurement Stopped by Controller' or 'Measurement
Interrupted' is displayed, this indicates the Drive Enable (I7) input
was dropped during the procedure.
User dropped the run command.
Controller dropped the run command.
Controller timeout due to run command and no movement.
Controller speed following error if controller inspection
speed not set to zero.
Check Event Log to see if a drive fault occurred and troubleshoot
the fault as necessary.